Skip to main navigation Skip to search Skip to main content

Aortic Cannulation in DeBakey Type I Aortic Dissection Facilitates Subsequent Deployment of a Frozen Elephant Trunk

  • Jonathan M. Hemli
  • , Allan Mattia
  • , Eden Payabyab
  • , Yuriy Dudiy
  • , S. Jacob Scheinerman
  • , Derek R. Brinster
  • Lenox Hill Hospital
  • Virginia Commonwealth University

Research output: Contribution to journal › Article › peer-review

Abstract

Arterial cannulation in acute DeBakey type I dissection can be difficult. Moreover, the residual dissected aorta is susceptible to further adverse events in the future. Implanting a stent-graft into the descending aorta during the initial dissection repair (‘frozen elephant trunk’) has been demonstrated to promote favourable aortic remodelling, mitigating some of these longer-term complications. We describe a technique for cannulation of the ascending aorta in acute dissection that facilitates expeditious antegrade deployment of a frozen elephant trunk.

Original languageEnglish
Pages (from-to)767-770
Number of pages4
JournalHeart Lung and Circulation
Volume27
Issue number6
DOIs
StatePublished - Jun 2018

Keywords

  • Aortic dissection
  • Cannulation
  • Elephant trunk
  • Stent-graft

Fingerprint

Dive into the research topics of 'Aortic Cannulation in DeBakey Type I Aortic Dissection Facilitates Subsequent Deployment of a Frozen Elephant Trunk'. Together they form a unique fingerprint.

Cite this