Skip to main navigation Skip to search Skip to main content

Coronary Access After TAVR-in-TAVR as Evaluated by Multidetector Computed Tomography

  • Ole De Backer
  • , Uri Landes
  • , Andreas Fuchs
  • , Sung Han Yoon
  • , Ole Norling Mathiassen
  • , Alexander Sedaghat
  • , Won Keun Kim
  • , Thomas Pilgrim
  • , Nicola Buzzatti
  • , Philipp Ruile
  • , Abdallah El Sabbagh
  • , Marco Barbanti
  • , Claudia Fiorina
  • , Luis Nombela-Franco
  • , Arie Steinvil
  • , Ariel Finkelstein
  • , Matteo Montorfano
  • , Pal Maurovich-Horvat
  • , Klaus Fuglsang Kofoed
  • , Philipp Blanke
  • Matjaz Bunc, Franz Josef Neumann, Azeem Latib, Stephan Windecker, Jan Malte Sinning, Bjarne Linde Norgaard, Raj Makkar, John G. Webb, Lars Søndergaard
  • University of Copenhagen
  • Providence Health Care Canada
  • Tel Aviv University
  • Aarhus University
  • University of Bonn
  • Kerckhoff Heart Center
  • University of Bern
  • San Raffaele Scientific Institute
  • University of Freiburg
  • Mayo Clinic Rochester, MN
  • A.O.U. Policlinico “G. Rodolico – San Marco,”
  • Brescia Civil Hospital
  • Hospital Clínico San Carlos de Madrid
  • Tel Aviv Sourasky Medical Center
  • Semmelweis University
  • University Medical Centre Ljubljana
  • Albert Einstein College of Medicine
  • Cedars-Sinai Medical Center

Research output: Contribution to journal › Article › peer-review

109 Scopus citations

Abstract

Objectives: The aim of this study was to assess coronary accessibility after transcatheter aortic valve replacement (TAVR)–in–TAVR using multidetector computed tomography. Background: Expanding TAVR to patients with longer life expectancy may involve more frequent bioprosthetic valve failure and need for redo TAVR. Coronary access after TAVR-in-TAVR may be challenging, particularly as the leaflets from the initial transcatheter heart valve (THV) will form a neo-skirt following TAVR-in-TAVR. Methods: In 45 patients treated with different combinations of CoreValve and Evolut (CV/EV) THVs with supra-annular leaflet position and SAPIEN THVs with intra-annular leaflet position, post-TAVR-in-TAVR multidetector computed tomographic scans were analyzed to examine coronary accessibility. Results: After TAVR-in-TAVR, the coronary arteries originated below the top of the neo-skirt in 90% of CV/EV-first cases compared with 67% of SAPIEN-first cases (p = 0.009). For these coronary arteries originating below the top of the neo-skirt, the distance between the THV and the aortic wall was <3 mm in 56% and 25% of CV/EV-first and SAPIEN-first cases, respectively (p = 0.035). Coronary access may be further complicated by THV-THV stent frame strut misalignment in 53% of CV/EV-in-CV/EV cases. The risk for technically impossible coronary access was 27% and 10% in CV/EV-first and SAPIEN-first cases, respectively (p = 0.121). Absence of THV interference with coronary accessibility can be expected in 8% and 33% of CV/EV-first and SAPIEN-first cases, respectively (p = 0.005). Conclusions: Coronary access after TAVR-in-TAVR may be challenging in a significant proportion of patients. THVs with intra-annular leaflet position or low commissural height and large open cells may be preferable in terms of coronary access after TAVR-in-TAVR.

Original languageEnglish
Pages (from-to)2528-2538
Number of pages11
JournalJACC: Cardiovascular Interventions
Volume13
Issue number21
DOIs
StatePublished - 9 Nov 2020

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • computed tomography
  • coronary access
  • transcatheter aortic valve

Fingerprint

Dive into the research topics of 'Coronary Access After TAVR-in-TAVR as Evaluated by Multidetector Computed Tomography'. Together they form a unique fingerprint.

Cite this