Abstract
A 40-year-old man with a type B aortic dissection from the distal left subclavian to right common iliac artery, involving the renal arteries, underwent an endovascular repair complicated with distal malperfusion owing to true lumen compression. A cheese-wire fenestration was done distal to the stent graft down to the aortic bifurcation with bilateral femoral thrombectomy. At postoperative 57 month, he developed a dissection flap in the distal ascending aorta that was repaired with a 28-mm Terumo Gelweave graft. True lumen compression from a reentry tear distal to a stent graft can be managed acutely with a cheese-wire endovascular fenestration with minimal specialized instruments.
| Original language | English |
|---|---|
| Article number | 102055 |
| Journal | Journal of Vascular Surgery Cases, Innovations and Techniques |
| Volume | 12 |
| Issue number | 1 |
| DOIs | |
| State | Published - Feb 2026 |
Keywords
- Dynamic
- Endovascular fenestration
- Endovascular repair
- Obstruction
- True lumen collapse
- Type B aortic dissection
Fingerprint
Dive into the research topics of 'Distal true lumen compression after thoracic endovascular aortic repair for aortic dissection treated with endovascular fenestration'. Together they form a unique fingerprint.Cite this