Skip to main navigation Skip to search Skip to main content

Orbital atherectomy for symptomatic lower extremity disease

  • Ravikiran Korabathina
  • , Kanika P. Mody
  • , Jennie Yu
  • , Seol Young Han
  • , Ruchika Patel
  • , Cezar S. Staniloae
  • Saint Vincent Catholic Medical Centers

Research output: Contribution to journal › Article › peer-review

34 Scopus citations

Abstract

Background. Plaque-debulking technologies have been proposed as alternative treatment options for peripheral arterial disease. Orbital atherectomy (OA), using the DiamondBack360® device, has emerged as one promising modality. Methods. We evaluated the safety and efficacy of OA in the first 200 lesions treated at our institution. Patient demographics, clinical characteristics, and lesion and procedural variables were collected and analyzed. The primary safety endpoint was the 30-day major adverse events (MAE), including death, myocardial infarction, stroke, unplanned amputation, or target lesion revascularization. Other safety endpoints included access-site complications, occurrence of dissections, perforations, distal embolization, spasm, and hemolysis. The efficacy endpoints were procedural success, need for adjunctive therapy, and improvement in ankle-brachial index. Multivariate analysis was performed to find independent predictors of the safety endpoints. Results. One hundred seventeen (58.5%) lesions were femoral, 31 (15.5%) were popliteal, and 52 (26.0%) were tibial. The procedural success (residual stenosis ≤30%) was comparable between the femoral and tibial lesions (86.3% vs. 92.5%, P = 0.18), but significantly lower for the popliteal lesions when compared with femoral and tibial (64.7% vs. 86.3%, P = 0.058, and 64.7% vs. 92.5%, P = 0.007 respectively). MAE at 30-days occurred in 3 (2.2%) procedures, and major access-site complications also occurred in 3 (2.2%). There were 31 (15.5%) dissections; independent predictors were diabetes mellitus (OR: 7.3, P = 0.008), crown-to-RVD ratio <0.6 (OR: 11.6, P = 0.005), and atherectomy time >360 sec (OR: 11.8, P = 0.001). There were 2 (1.0%) distal embolizations, 6 (3.0%) arterial spasms, and no perforations. Laboratory evidence of hemolysis was noted in 33.8% of cases. Conclusion. Orbital atherectomy allows for a significant procedural success, limited need for stenting, and favorable safety profile.

Original languageEnglish
Pages (from-to)326-332
Number of pages7
JournalCatheterization and Cardiovascular Interventions
Volume76
Issue number3
DOIs
StatePublished - 1 Sep 2010

UN SDGs

This output contributes to the following UN Sustainable Development Goals (SDGs)

  1. SDG 3 - Good Health and Well-being
    SDG 3 Good Health and Well-being

Keywords

  • Atherectomy
  • ATHR
  • Peripheral vascular disease
  • PVD
  • Quantitative vascular angiography
  • QVA

Fingerprint

Dive into the research topics of 'Orbital atherectomy for symptomatic lower extremity disease'. Together they form a unique fingerprint.

Cite this