Skip to main navigation Skip to search Skip to main content

Surgical Mitral Valve Repair vs Replacement After Failed Mitral Transcatheter Edge-to-Edge Repair: The CUTTING-EDGE Registry

  • CUTTING-EDGE Investigators
  • Fresenius AG
  • Technical University of Munich
  • German Centre for Cardiovascular Research
  • University of Hamburg
  • Ludwig Maximilian University of Munich
  • HerzZentrum Hirslanden Zürich
  • Baptist Health Miami Heart and Vascular Institute
  • University of Virginia
  • University of Michigan, Ann Arbor
  • Baylor Scott & White Health
  • University of Montreal
  • Emory University
  • Columbia University
  • European Institute for Research in Cystic Fibrosis
  • Centre Hospitalier Universitaire de Bordeaux
  • Houston Methodist
  • Allina Health
  • Washington University St. Louis
  • Mount Sinai Hospital Medical Center
  • Baylor College of Medicine
  • Deutsches Herzzentrum Berlin
  • Universidade Federal do Rio Grande do Sul
  • University of Texas Southwestern Medical Center
  • Mount Sinai Medical Center Miami Beach
  • Baylor Health Care System
  • Vanderbilt University
  • CHU de Rennes

Research output: Contribution to journal › Article › peer-review

12 Scopus citations

Abstract

Background: The impact of mitral valve (MV) surgery type after failed mitral transcatheter edge-to-edge repair (M-TEER) has not been well studied. Objectives: The aim of this study was to compare the outcomes of MV repair vs replacement after failed M-TEER. Methods: From 2009 to 2020, a total of 332 patients across 34 centers from the CUTTING-EDGE registry underwent MV surgery after M-TEER. Outcomes were compared between MV repair and replacement. Primary outcomes included 30-day mortality and 1-year survival after MV surgery. Results: Among enrolled patients (mean age 73.8 ± 10.1 years, median Society of Thoracic Surgeons Predicted Risk of Mortality 3.9% [Q1-Q3: 2.2%-6.8%]), 25 (7.5%) underwent repair and 307 (92.5%) underwent replacement. The replacement group had a significantly higher rate of comorbidities, including atrial fibrillation, prior cardiac surgery, more secondary mitral regurgitation, and more devices implanted at index M-TEER (P < 0.05 for all). Replacement patients showed a trend toward higher 30-day mortality (17.7% [52 of 294] vs 4.0% [1 of 25]; P = 0.094). The observed-to-expected ratio of 30-day mortality was 3.6 (95% CI: 1.9-5.3) overall, 3.8 (95% CI: 2.1-5.5) in the replacement group, and 1.7 (95% CI: 0.7-3.3) in the repair group. Replacement patients had higher 1-year mortality (33.3% [65 of 195] vs 10.5% [2 of 19]; P = 0.041). Significantly lower survival rates were observed after replacement at 2 years (P = 0.033) and persisted in the risk-adjusted Cox regression analysis (HR for replacement: 4.24; 95% CI: 1.04-17.31; P = 0.044). Conclusions: MV surgery after failed M-TEER is a high-risk procedure associated with higher than expected 30-day mortality, with higher mortality associated with MV replacement. Compared with repair, replacement is associated with higher 1-year mortality and a lower 2-year survival.

Original languageEnglish
Pages (from-to)912-923
Number of pages12
JournalJACC: Cardiovascular Interventions
Volume18
Issue number7
DOIs
StatePublished - 14 Apr 2025

Keywords

  • mitral valve repair
  • mitral valve replacement
  • mitral valve surgery
  • transcatheter edge-to-edge repair

Fingerprint

Dive into the research topics of 'Surgical Mitral Valve Repair vs Replacement After Failed Mitral Transcatheter Edge-to-Edge Repair: The CUTTING-EDGE Registry'. Together they form a unique fingerprint.

Cite this